English
English Chinese Simplified Chinese Traditional French German Portuguese Spanish Russian Japanese Korean Arabic Irish Greek Turkish Italian Danish Romanian Indonesian Czech Afrikaans Swedish Polish Basque Catalan Esperanto Hindi Lao Albanian Amharic Armenian Azerbaijani Belarusian Bengali Bosnian Bulgarian Cebuano Chichewa Corsican Croatian Dutch Estonian Filipino Finnish Frisian Galician Georgian Gujarati Haitian Hausa Hawaiian Hebrew Hmong Hungarian Icelandic Igbo Javanese Kannada Kazakh Khmer Kurdish Kyrgyz Latin Latvian Lithuanian Luxembou.. Macedonian Malagasy Malay Malayalam Maltese Maori Marathi Mongolian Burmese Nepali Norwegian Pashto Persian Punjabi Serbian Sesotho Sinhala Slovak Slovenian Somali Samoan Scots Gaelic Shona Sindhi Sundanese Swahili Tajik Tamil Telugu Thai Ukrainian Urdu Uzbek Vietnamese Welsh Xhosa Yiddish Yoruba Zulu Kinyarwanda Tatar Oriya Turkmen Uyghur Abkhaz Acehnese Acholi Alur Assamese Awadish Aymara Balinese Bambara Bashkir Batak Karo Bataximau Longong Batak Toba Pemba Betawi Bhojpuri Bicol Breton Buryat Cantonese Chuvash Crimean Tatar Sewing Divi Dogra Doumbe Dzongkha Ewe Fijian Fula Ga Ganda (Luganda) Guarani Hakachin Hiligaynon Hunsrück Iloko Pampanga Kiga Kituba Konkani Kryo Kurdish (Sorani) Latgale Ligurian Limburgish Lingala Lombard Luo Maithili Makassar Malay (Jawi) Steppe Mari Meitei (Manipuri) Minan Mizo Ndebele (Southern) Nepali (Newari) Northern Sotho (Sepéti) Nuer Occitan Oromo Pangasinan Papiamento Punjabi (Shamuki) Quechua Romani Rundi Blood Sanskrit Seychellois Creole Shan Sicilian Silesian Swati Tetum Tigrinya Tsonga Tswana Twi (Akan) Yucatec Maya
Leave Your Message

KWS Medium Efficiency Panel-Type Pleated Filter

Name KWS Medium Efficiency Panel-Type Pleated Filter
Model Number KWS-011 AIR filter
Color Red/Green
Dimensions 595*595*46/295*595*46
Net Weight customized
Material The outer frame is made of aluminium or galvanised  frame,High-Efficiency Composite Wire Mesh with Synthetic Fiber Reinforcement
Applications air purifier filters
Brand Name KWS or OEM
Origin Xiamen, China (mainland)

    Strategic Positioning & Performance Thresholds

    As the core filtration hub in central HVAC and cleanroom systems, medium efficiency pleated filters (F5-F9 class) are engineered to capture 0.5-5μm particulate matter with critical performance-impacting parameters:

    1.Efficiency Spectrum: 60%-95% (for 0.5μm particles at F9 grade)

    2.Resistance Limits: Initial resistance ≤50Pa; Mandatory replacement at ≥250Pa final resistance

    3.Actual Dust Holding Capacity: Rated value × 0.7 conversion factor (accounting for skin flakes/textile fibers in real-world contaminants)

    Industry Alert: Substandard F7 filters cause 42% of premature HEPA failures (ASHRAE 2023 Field Study).

    Triple Breakthroughs in Structural Innovation

    ▶ Pleat Geometry Revolution 80mm deep pleats increase effective filtration area by 150% vs. conventional 50mm designs Laser-aligned molds ensure 2.5mm uniform pleat spacing with >85% airflow uniformity
    ▶ Filter Media Evolution 3rd Gen Nanofiber Electret PP: Dual-mode capture (electrostatic + mechanical) reduces PM1.0 penetration by 37% Glass Fiber Composite: Gradient density (0.8→1.2g/cm³) ensures stability
    ▶ Sealing Engineering Polyurethane gasket compression ratio: 35%±2% (validated at -30°C/80°C) Metal frames pass 72hr salt spray test per ASTM B117 (zero white rust)

    Mission-Critical Application Protocols

    ▌Pharmaceutical GMP Suites PAO aerosol scan testing leakage <0.01% (ISO 14644-3 compliant) Frame materials require USP Class VI biocompatibility certification
    ▌Data Centers Nano-hydrophobic coating (contact angle >120°) prevents humidity failure UL900 Class1 flame spread rating <152mm/min
    ▌Paint Booths Silane-modified media resists xylene degradation 80μm epoxy-coated steel frames combat solvent corrosion

    Golden Rules Forged from 20-Year Field Experience

    Sizing Formula: Actual airflow × 1.2 < Rated airflow (1.8-2.2m/s face velocity) End-of-Life Triggers: Resistance doubles initial ΔP OR downstream particles increase >15% weekly
    Maintenance Prohibition: Water washing causes fiber rupture with 40% efficiency degradation!

    Lifecycle Cost Optimization Philosophy

    Field data proves: Each F-grade improvement (e.g., F7→F8) reduces system energy consumption by 8% annually and extends HEPA replacement cycles by 6-9 months. Premium medium filters deliver 53% lower 5-year TCO versus substandard products.

    Product Characteristics
    1.Coarse dust filtration, pre-filter for air filtration systems;
    2.Synthetic fiber pleated filter;
    3.Reusable after cleaning;
    4.Also suitable for air conditioning and ventilation systems requiring only primary filtration.

    Applications
    1.Intermediate filtration for air conditioning systems; air filtration for spray lines;
    2.Air filtration for electronics, chemical, food, and other industries;
    3.Primary filtration for residential air conditioning purification equipment.

    Technical parameters

    NAME

    Size

    Rated airflow

    efficiency

    initial resistance

    Suggested ultimate resistance

    KWS-011

    595*595*46

    3000m³/h

    F7(85%)

    ≦55Pa

    ≦110Pa

    KWS-012

    295*595*46

    1500m³/h

    F7(85%)

    ≦55Pa

     

    ≦110Pa

    KWS-013

    595*595*22

    3000m³/h

    F7(85%)

    ≦55Pa

     

    ≦110Pa

     

    KWS-014

    295*595*22

    1500m³/h

    F7(85%)

    ≦55Pa

     

    ≦110Pa

     